Blocking the Software from Updating the Customized RMAN Script

When you perform a full or incremental backup on a subclient that has the table browse option enabled and the job is killed or fails, the software converts a subsequent incremental job to full. If you used a customized RMAN script for the incremental backup, the software adds  the "incremental=1" line to the script. If the previous job failed, the software automatically changes the line to “incremental level=0” to convert the job to a full backup.

Set sDISABLE_INRC_LEVEL_UPDATE to Y, to block the software from updating the RMAN script incremental level to 0 when the previous job failed in the archive index phase.

Note: The job controller shows the job as a full job even though it ran as an incremental job.

Procedure

  1. From the CommCell Browser, right-click the CommServe, and click Properties.
  2. On the Properties dialog box click Advanced.
  3. On the Additional Settings tab of the Properties dialog box and click Add.
    1. In the Name field, type sDISABLE_INRC_LEVEL_UPDATE.
    2. In the Category box, select CommServe from the list.
    3. In the Type box, select String.
    4. In the Value box, specify whether the software updates the customized RMAN script

      To allow the update, type N. To block the update, type Y.

    5. Click OK to close the Additional Settings dialog box.
  4. Click OK to close the Propertiesdialog box.